Circuit breaker – Yueqing Weixin Electric Technology Co., Ltd https://www.lewsin.com Power stabilizer Fri, 09 May 2025 07:11:45 +0000 en-US hourly 1 https://wordpress.org/?v=7.1 High breaking miniature circuit breaker https://www.lewsin.com/?p=7948&lang=en https://www.lewsin.com/?p=7948&lang=en#respond Thu, 29 Jun 2023 08:57:05 +0000 https://www.lewsin.com/?p=7948 product type miniature circuit breaker number of poles 1P/2P/3P/4P Product Application Distribution protection Number of protection poles 1,2,3,4 Rated current (In) 100 A at… 30 ° C Type of release device thermo-magnetic Release curve C Breaking Capacity 10 kA Icu on… 440 V AC 50/60 Hz in accordance with IEC 60947-2
30 kA Icu on… 230… 240 V AC 50/60 Hz in accordance with IEC 60947-2
15 kA Icu on… 400… 415 V AC 50/60 Hz in accordance with IEC 60947-2
15000 A Icn on… 400 V AC 50/60 Hz in accordance with IEC 60898-1 Isolation function Applicable in accordance with IEC 60947-2 main information
Network frequency 50/60 Hz
Rated working voltage [Ue] 230 V AC/400 V AC 50/60 Hz
Magnetic release limit 5…10 x In
Current limiting level 3. Complies with IEC 60898-1
Rated insulation voltage [Ui] 500 V AC 50/60 Hz in accordance with IEC 60947-2
Rated impulse withstand voltage [Uimp] 6 kV complies with IEC 60947-2
Contact position indication have
control type handle
Local signal indication On/off indication
Installation type Locking clip locking
Installation method DIN rail installation
mechanical life 20000 times
Electrical life 5000 times
Wiring ability Tunnel type terminal with upper or lower wiring 1… 50 mm ² single stranded hard wire without wire terminal
Tunnel terminal with or without wire connection, 1.5… 35 mm ² flexible wire (optional)
]]>
https://www.lewsin.com/?feed=rss2&p=7948&lang=en 0
High breaking miniature circuit breaker C65 https://www.lewsin.com/?p=7942&lang=en https://www.lewsin.com/?p=7942&lang=en#respond Thu, 29 Jun 2023 08:54:36 +0000 https://www.lewsin.com/?p=7942 product type miniature circuit breaker number of poles 3P Product Application Distribution protection Number of protection poles 3 Rated current [In] 100 A at… 30 ° C Network AC Type of release device thermo-magnetic Release curve C Breaking Capacity 10 kA Icu on… 440 V AC 50/60 Hz in accordance with IEC 60947-2
30 kA Icu on… 230… 240 V AC 50/60 Hz in accordance with IEC 60947-2
15 kA Icu on… 400… 415 V AC 50/60 Hz in accordance with IEC 60947-2
15000 A Icn on… 400 V AC 50/60 Hz in accordance with IEC 60898-1 Isolation function Applicable in accordance with IEC 60947-2 main information
Network frequency 50/60 Hz
Rated working voltage [Ue] 400 V AC 50/60 Hz
Magnetic release limit 5…10 x In
Current limiting level 3. Complies with IEC 60898-1
Rated insulation voltage [Ui] 500 V AC 50/60 Hz in accordance with IEC 60947-2
Rated impulse withstand voltage [Uimp] 6 kV complies with IEC 60947-2
Contact position indication have
control type handle
handle On/off indication
On/off indication Locking clip locking
Installation method DIN rail installation
Supplementary Information
mechanical life 20000 times
Electrical life 5000 times
Wiring ability Tunnel type terminal with upper or lower wiring 1… 50 mm ² single stranded hard wire without wire terminal
Tunnel terminal with or without wire connection, 1.5… 35 mm ² flexible wire (optional)
]]>
https://www.lewsin.com/?feed=rss2&p=7942&lang=en 0
PG-20A https://www.lewsin.com/?p=7936&lang=en https://www.lewsin.com/?p=7936&lang=en#respond Thu, 29 Jun 2023 08:51:47 +0000 https://www.lewsin.com/?p=7936 The CM1 series circuit breaker is mainly used for overload, undervoltage, and short circuit protection of distribution lines and power equipment in distribution networks with AC frequency of 50Hz-60Hz, rated insulation voltage of 800V, rated working voltage of 690V and below, and rated current of 1250A and below. Plastic shell circuit breakers with 400A shell level and below can also be used for motor overload, undervoltage, and short circuit protection. Under normal circumstances, it can be used for infrequent switching of circuits and infrequent starting of motors.
This series of circuit breakers has the characteristics of small size, high short-circuit breaking capacity, small arcing distance, and anti vibration. When the overload current or short-circuit current reaches or exceeds its specified value, the circuit breaker will automatically trip, thereby cutting off the power supply and protecting the equipment on the load side.
Special Model Description:
Type C: Basic, able to meet basic requirements;
S-type: Standard type (equivalent to L-type) suitable for use in power systems with 10 times the current and most occasions;
M-type: higher breaking type, used for motor starting and protection, and power cabinet;
H-type: High segment type, suitable for 12 times trip current and motor protection;

]]>
https://www.lewsin.com/?feed=rss2&p=7936&lang=en 0
CM1 molded case circuit breaker https://www.lewsin.com/?p=7931&lang=en https://www.lewsin.com/?p=7931&lang=en#respond Thu, 29 Jun 2023 08:45:50 +0000 https://www.lewsin.com/?p=7931 The CM1 series circuit breaker is mainly used for overload, undervoltage, and short circuit protection of distribution lines and power equipment in distribution networks with AC frequency of 50Hz-60Hz, rated insulation voltage of 800V, rated working voltage of 690V and below, and rated current of 1250A and below. Plastic shell circuit breakers with 400A shell level and below can also be used for motor overload, undervoltage, and short circuit protection. Under normal circumstances, it can be used for infrequent switching of circuits and infrequent starting of motors.
This series of circuit breakers has the characteristics of small size, high short-circuit breaking capacity, small arcing distance, and anti vibration. When the overload current or short-circuit current reaches or exceeds its specified value, the circuit breaker will automatically trip, thereby cutting off the power supply and protecting the equipment on the load side.
Special Model Description:
Type C: Basic, able to meet basic requirements;
S-type: Standard type (equivalent to L-type) suitable for use in power systems with 10 times the current and most occasions;
M-type: higher breaking type, used for motor starting and protection, and power cabinet;
H-type: High segment type, suitable for 12 times trip current and motor protection;

]]>
https://www.lewsin.com/?feed=rss2&p=7931&lang=en 0
C45 miniature circuit breaker https://www.lewsin.com/?p=7924&lang=en https://www.lewsin.com/?p=7924&lang=en#respond Thu, 29 Jun 2023 08:43:50 +0000 https://www.lewsin.com/?p=7924 product type miniature circuit breaker number of poles 1P/2P/3P/4P Product Application Distribution protection Number of protection poles 1,2,3,4 Rated current (In) 100 A at… 30 ° C Type of release device thermo-magnetic Release curve C Breaking Capacity 10 kA Icu on… 440 V AC 50/60 Hz in accordance with IEC 60947-2
30 kA Icu on… 230… 240 V AC 50/60 Hz in accordance with IEC 60947-2
15 kA Icu on… 400… 415 V AC 50/60 Hz in accordance with IEC 60947-2
15000 A Icn on… 400 V AC 50/60 Hz in accordance with IEC 60898-1 Isolation function Applicable in accordance with IEC 60947-2 main information
Network frequency 50/60 Hz
Rated working voltage [Ue] 230 V AC/400 V AC 50/60 Hz
Magnetic release limit 5…10 x In
Current limiting level 3. Complies with IEC 60898-1
Rated insulation voltage [Ui] 500 V AC 50/60 Hz in accordance with IEC 60947-2
Rated impulse withstand voltage [Uimp] 6 kV complies with IEC 60947-2
Contact position indication have
control type handle
Local signal indication On/off indication
Installation type Locking clip locking
Installation method DIN rail installation
mechanical life 20000 times
Electrical life 5000 times
Wiring ability Tunnel type terminal with upper or lower wiring 1… 50 mm ² single stranded hard wire without wire terminal
Tunnel terminal with or without wire connection, 1.5… 35 mm ² flexible wire (optional)
]]>
https://www.lewsin.com/?feed=rss2&p=7924&lang=en 0
CM1 molded case circuit breaker https://www.lewsin.com/?p=7917&lang=en https://www.lewsin.com/?p=7917&lang=en#respond Thu, 29 Jun 2023 08:26:12 +0000 https://www.lewsin.com/?p=7917 The CM1 series circuit breaker is mainly used for overload, undervoltage, and short circuit protection of distribution lines and power equipment in distribution networks with AC frequency of 50Hz-60Hz, rated insulation voltage of 800V, rated working voltage of 690V and below, and rated current of 1250A and below. Plastic shell circuit breakers with 400A shell level and below can also be used for motor overload, undervoltage, and short circuit protection. Under normal circumstances, it can be used for infrequent switching of circuits and infrequent starting of motors.
This series of circuit breakers has the characteristics of small size, high short-circuit breaking capacity, small arcing distance, and anti vibration. When the overload current or short-circuit current reaches or exceeds its specified value, the circuit breaker will automatically trip, thereby cutting off the power supply and protecting the equipment on the load side.
Special Model Description:
Type C: Basic, able to meet basic requirements;
S-type: Standard type (equivalent to L-type) suitable for use in power systems with 10 times the current and most occasions;
M-type: higher breaking type, used for motor starting and protection as well as power cabinet;
H-type: High segment type, suitable for 12 times trip current and motor protection;

]]>
https://www.lewsin.com/?feed=rss2&p=7917&lang=en 0